Analytical Formulations
Texas laboratory (Analytical Formulations, Inc., an active Texas corporation chartered in March 2008) at 8940 Fourwinds Drive, Windcrest. Its reports reach readers mainly through Purity Analytics, a platform that orders tests from laboratories and re-issues the results under its own digital signature; the platform's records confirm the document with the platform, not with this laboratory, which offers no public lookup of its own. Identity on the reports we read is by UV-Vis wavelength match, not mass spectrometry. No accreditation is documented (checked 22 October 2026). Methods: UV-Vis (Lambda Max identification and Beer-Lambert assay) on most reports; HPLC-UV and LC-MS on some lots.
- Vendors with its COAs
- 1
Vendors with its COAs
- Peptides tested
- 12
Peptides tested
Tier C
Windcrest, TX (8940 Fourwinds Drive, Suite 107)
Checks run
- BusinessL1 Real business: Pass
- IndependentL2 Independence: Pass
- Verify routeL3 Verification route: Fail
- MethodL4 Identity method: Partial
- Track recordL5 Track record: Fail
- AccreditedL6 Accreditation: Fail
Six published checks, the same for every laboratory. Results and evidence
About Analytical Formulations
Analytical Formulations is an independent analytical lab based in Windcrest, TX (8940 Fourwinds Drive, Suite 107), rated tier C in the Peptide Source Review lab directory. No accreditation documented; none found on the A2LA, PJLA or ANAB registers (checked 22 October 2026). Tier C laboratories earn a certificate no laboratory points (the +2 needs tier B- or better), though the certificate's other points still count.
1 US peptide vendor in our audit publishes certificates naming Analytical Formulations, led by Based Research at 4.54/10. The reports cover UV-Vis (Lambda Max identification and Beer-Lambert assay) on most reports; HPLC-UV and LC-MS on some lots.
How we graded Analytical Formulations
Each check is the same for every laboratory (the rules). Checked 2026-10-22.
| Result | Check | What we found |
|---|---|---|
| Pass | L1 Real business | The Texas franchise-tax register lists ANALYTICAL FORMULATIONS, INC., chartered 2008-03-11, active; its site gives 8940 Fourwinds Drive, Suite 107, Windcrest, TX.Evidence for L1 (opens in new tab)data.texas.govchecked |
| Pass | L2 Independence | analyticalformulations.com was registered 2025-11-15, before its earliest report (2026-02-28); two unrelated ordering parties; no link to a listed vendor found.Evidence for L2 (opens in new tab)rdap.orgchecked |
| Fail | L3 Verification route | No laboratory lookup for its reports; the copies we hold are re-signed by Purity Analytics, a separate platform.Evidence for L3 (opens in new tab)verify.purityanalytics.comchecked |
| Partial | L4 Identity method | Identity 'Qualitative ID - Lambda Max' by UV-Vis; no mass spectrometry.Evidence for L4 (opens in new tab)api.purityanalytics.comchecked |
| Fail | L5 Track record | Earliest report 2026-02-28; two clients.Evidence for L5 (opens in new tab)api.purityanalytics.comchecked |
| Fail | L6 Accreditation | No accreditation is claimed, and the A2LA, PJLA and ANAB registers have no entry for it.Evidence for L6 (opens in new tab)customer.a2la.orgchecked |
No accreditation documented; none found on the A2LA, PJLA or ANAB registers (checked 22 October 2026)
Vendors publishing Analytical Formulations certificates
Peptides tested here
Products whose certificate on a vendor page names Analytical Formulations. Compare sources for each.
Similar labs
Other tier C labs in our directory.
Analytical Formulations: Frequently Asked Questions
Is Analytical Formulations accredited?
We have not confirmed ISO/IEC 17025 accreditation for Analytical Formulations that is active on the accrediting body's register with a scope covering peptide testing (check L6). No accreditation documented; none found on the A2LA, PJLA or ANAB registers (checked 22 October 2026).
Which peptide vendors use Analytical Formulations?
1 vendor in our independent audit publishes certificates naming Analytical Formulations: Based Research. The full list with scores is on this page.
What does Analytical Formulations test for?
Analytical Formulations performs UV-Vis (Lambda Max identification and Beer-Lambert assay) on most reports; HPLC-UV and LC-MS on some lots on research-peptide samples.